LSBio
Human ACTA2 / Smooth Muscle Actin ELISA Kit (Sandwich ELISA)

Sandwich ELISA Platform Overview

Human ACTA2 / Smooth Muscle Actin ELISA Kit (Sandwich ELISA)

Reactivity:Human
Detection MethodColorimetric
Format:96-Well Strip Plate
See all ACTA2 / Smooth Muscle Actin antibodies →
$799.00each
Catalog Number: LS-F13051-1

For bulk orders or custom formulations:

Request a Quote

Overview

Description
ACTA2 / Smooth Muscle Actin ELISA Kit LS-F13051 is a 96-Well enzyme-linked immunosorbent assay for the Quantitative detection of Human ACTA2 / Smooth Muscle Actin in Cell Culture Supernatants, Plasma, Serum, Tissue Homogenates. It is a Sandwich assay which can detect down to 3. For Research Use Only
Reactivity
Hu
Intended Use
Research Use Only
Category
ELISA Kits > Traditional ELISA Kits
Alternative Names
ACTA2 | ACTVS | Alpha-actin-2 | Alpha-cardiac actin | AAT6 | Actin, aortic smooth muscle | ACTSA | Smooth Muscle Actin | MYMY5 | SMA

Assay Performance

Detection Method
Colorimetric
Assay Type
Quantitative
Assay Format
Sandwich Enzyme-Linked Immunosorbent Assay
Sensitivity
1.56 ng/ml
Detection Range
3.12 - 200 ng/ml
Intra-Assay CV%
<5.2%
Inter-Assay CV%
<9.2%
Compatible Sample Types
Cell Culture Supernatant, Plasma, Serum, Tissue Homogenate
Detection Wavelength (Colorimetric)
450 nm
About This Kit
Due to their limited shelf life, LSBio ELISA kits are not typically stocked as finished goods. Upon receipt of an order each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Range, Sensitivity, and Precision. In the event of a significant change the order would be confirmed with the customer before shipping ELISA kit lot numbers reflect the date of final assembly and testing for each specific kit rather than a bulk manufactured lot. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.

Format

Format
96-Well Strip Plate
Kit Components
Coated 96-well Strip Plate, Standard (Lyophilized), Sample Diluent, Assay Diluent A, Assay Diluent B, Detection Reagent A, Detection Reagent B, TMB Substrate, Stop Solution, Adhesive Plate Sealers, Wash Buffer (25x)

Storage & Handling

Storage Conditions
Short term: 4°C; Long term: see manual.

Documentation

Manuals
Manual
Mural cell dysfunction leads to altered cerebrovascular tau uptake following repetitive head trauma. Joseph Ojo, Max Eisenbaum, Ben Shackleton, Cillian Lynch, Utsav Joshi, Nicole Saltiel, Andrew Pearson, Charis Ringland, Daniel Paris, Benoit Mouzon, Michael Mullan, Fiona Crawford, Corbin Bachmeier. Neurobiology of disease. 2021 Mar;;150:105237. PubMed: 33383188 PMC: PMC8170787

Request SDS/MSDS